Online Catalog
A collection of nonclinical studies & assays; customization is possible.

Wettability for physical chemistry testing

Wettability (CIPAC MT 53.3) ascertains whether products formulated as water-soluble, wettable, emulsifiable or dispersible powders/granules for spraying are wetted fast enough in use. Using quantities that will produce the highest intended concentration, the formulated product is dropped into to water from a specified height and without stirring; the time to complete wetting is then determined. Depending on the type of formulation, an acceptable test result is complete wetting within either one or two minutes.

Industry Market

Crop

Phase

Nonclinical